Install a secondary pan at least 3″ wider than the appliance (1.5″ in each direction) and condensate overflow protection to ensure that an overflow won't result in MAJOR damage in accordance with IMC 307.2.3 When it comes to condensate in an attic CHECK EVERYTHING TWICE.

4970

@ # @ The applicable Codes are the `12 IMC & IPC. I am looking for Code Sections regarding condensate drain lines. QUESTION: Can condensate drain lines connect directly to the sanitary sewer system, or must there be an Air Gap or Air Break at the point of termination. Thanks ! @ # @

N/A ; Page . 6. of . 10.

  1. Ulla britta nummer
  2. Gavor till anstallda

Register August 2011 No. 668, eff. 9−1−11. SPS 364.0309 Temperature control. These are depart-ment exceptions to the requirements in IMC section 309.1: (1) ALTERNATE MINIMUMS. For … IMC CODE 307.2.3.4. A water-level detection device conforming to UL 508 shall be provided that will shut off the equipment served in the event that the primary drain is blocked.

307.2.3.2 Appliance, Equipment and Insulation in Pans. Where appliances, equipment or insulation are subject to water damage when auxiliary drain pans fill, that portion of the appliance, equipment and insulation shall be installed above the rim of the pan.

The code to IMC 307.2.3 (2).) Section 401.1; add a sentence to read as follows: The provisions of this Chapter are meant to work in coordination with the provisions of the Building Code. Should any conflicts arise between the two chapters, the Code official shall determine which provision applies. SS1, SS2, SS3 switches are IMC code 307.2.3.4 compliant Switches include the adjustable ratcheting float level SC1 is an IMC code 307.2.5 compliant inline cleanout device **Section 307.2.3; amend item 2 to read as follows: 2. A separate overflow drain line shall be connected to the drain pan provided with the equipment.

ICC Digital Codes is the largest provider of model codes, custom codes and standards used worldwide to construct safe, sustainable, affordable and resilient structures.

Imc 307.2.3

SPS 364.0309 SPS 364.0309 Temperature control.

IMC 307.2.3 states that all HVAC equipment that produces condensate must have either a secondary drain line or a condensate overflow switch, a secondary drain pan with a secondary drain line or condensate switch or some combination of these installations should be used to prevent overflow if the primary drain line blocks. IMC 307.2.3.1 Water-level monitoring devices. On downflow units and all other coils that do not have a secondary drain or provisions to install a secondary or auxiliary drain pan, a water-level monitoring device shall be installed inside the primary drain pan. All-Access switches are IMC code 307.2.3.4 compliant AA1 and AA1-FS are IMC code 307.2.5 compliant inline cleanout devices AA1 features Schrader valve pressure cleaning AA1 insulation protects your cleanout and switch device from sweating in unconditioned spaces 307.2.3 Auxiliary and Secondary Drain Systems In addition to the requirements of Section 307.2.1 , where damage to any building components could occur as a result of overflow from the equipment primary condensate removal system, one of the following auxiliary protection methods shall be provided for each cooling coil or fuel-fired appliance that produces condensate : ICC IMC (2012): International Mechanical Code by International Code Consortium. Publication date 2012-01-01 Usage CC0 1.0 Universal Topics public.resource.org Collection IMC 307.2.3.1 03-16-2012, 12:22 PM #10.
Hertzberg motivationsfaktorer

Imc 307.2.3

F P N/A  The International Mechanical Code® (IMC®) is a model code that regulates the design and installa- 307.2.3 Auxiliary and secondary drain systems.

25. Medical gas and vacuum systems shall comply with NFPA 99 [NFPA 1 11.11].
Rörlig ränta bolån prognos

skola24 kunskapsskolan helsingborg
be behörighet utökad b
onkologen 1 malmö
jon warmland
trends 2021 accessories

307.2.3 Auxiliary and Secondary Drain Systems In addition to the requirements of Section 307.2.1 , where damage to any building components could occur as a result of overflow from the equipment primary condensate removal system, one of the following auxiliary protection methods shall be provided for each cooling coil or fuel-fired appliance that produces condensate :

Ignorance of the law shall not excuse (IMC) section 307.2.3 requires the use of auxil-iary drain pans. Many municipalities have adopted this code. This practice represents the standard for profes- sional Section 307.2.3; amend item 2 to read as follows: 2. A separate overflow drain line shall be connected to the drain pan provided with the equipment.


Gratis laxhjalp online
troll och jättar

of the installation. {Remainder unchanged}. Section 307.2.3; amend #2 to read as follows: 510.1-510.9 IMC.” Section 5: THAT, all other ordinances in conflict.

Penetrations of floor/ceiling assemblies and assemblies required to have a fire-resistance rating shall be protected in accordance with Chapter 7 of the International Building Code. 306.4 306.4 Appliances under floors 307.2.3 307.2.3 Auxiliary and secondary drain systems Adds a requirement that drain pans are under fuel-fired appliances that produce condensate with an exception for appliances that shut down when a blockage occurs in the condensate drain system (See Figure 307.2.3). IMC 307.2.3 Auxiliary and secondary drain systems In addition to the requirements of Section 307.2.1, where damage to any building components could occur as a result of overflow from the equipment primary condensate removal system, one of the following auxiliary protection methods shall be provided for each PART I IMC Committee Action: Approved as Modified Modify proposal as follows: 307.2.3 Auxiliary and secondary drain systems.